{"id":107845,"date":"2019-12-26T14:06:14","date_gmt":"2019-12-26T13:06:14","guid":{"rendered":"https:\/\/ziacom.com\/?p=107845"},"modified":"2022-11-30T10:21:26","modified_gmt":"2022-11-30T09:21:26","slug":"disassembling-zinicmt","status":"publish","type":"post","link":"https:\/\/ziacom.com\/en\/dental-implants\/disassembling-zinicmt\/","title":{"rendered":"Disassembling ZinicMT"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_raw_js]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[\/vc_raw_js][vc_column_text]<\/p>\n\n<p>[\/vc_column_text]<div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":50,\"mobile\":30,\"smobile\":30}'><\/div>[vc_column_text]<span data-contrast=\"auto\">The key to tapered implants such as the ZinicMT lies in their high primary stability, in other words, in the <strong>solidity and consistency<\/strong> they achieve <strong>at the bone-implant junction<\/strong>. Correct primary stability is essential for osseointegration, as it reduces the risk of micromovement and negative tissue response.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">To achieve this stability, the design of the implant is essential, which is the reason why ZinicMT has been through in every detail.\u00a0<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<h2><strong><span class=\"TextRun SCXW169708601 BCX0\" lang=\"EN-GB\" xml:lang=\"EN-GB\" data-contrast=\"auto\"><span class=\"NormalTextRun SpellingErrorV2 SCXW169708601 BCX0\">ZinicMT<\/span><span class=\"NormalTextRun SCXW169708601 BCX0\">, balance and stability for the wellness of your patient<\/span><\/span><span class=\"EOP SCXW169708601 BCX0\" data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/strong><\/h2>\n<p><span data-contrast=\"auto\">With an <strong>internal hexagonal connection<\/strong>, the physical and functional details of Zinic MT are designed to achieve optimal primary stability to ensure the success of the osseointegration process. The hexagonal shape of the connection also guarantees the proper fit of the abutment to the implant and a connection resistant to lateral loads, as well as excellent aesthetic results.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Thanks to its mechanical and surface factors, ZinicMT provides:<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Improvement of the<strong> distribution of longitudinal forces<\/strong> (hexagon depth of 1.5mm).<\/span><\/li>\n<li><strong>Reduction of bacterial infiltration<\/strong> (conical bevel).<\/li>\n<li>Reduction of micro-movements (conical friction).<\/li>\n<li>Soft tissue formation and <strong>emergence profile shaping<\/strong> (Platform Switch).<span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"auto\">Its cortical area is shaped by a 0.4mm mechanised ring that allows to raise the prosthetic gap according to the crestal bone in medium-thick biotypes and avoiding to expose the treated surface in irregular crest.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">In addition, its silhouette, which is similar to the natural root of the tooth,<strong> allows the implant to adapt completely to the abutment and provides an impeccable seal.<\/strong><\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">Its advantages also include:\u00a0<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Micro-thread design preserves marginal bone and improves load distribution.<\/span><\/li>\n<li>Macro design allows for optimal cortical compression.<\/li>\n<li>Reduced angle lead threads provide stability during insertion and increase BIC (bone-implant contact). <span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/li>\n<li>The double lead thread multiplies the insertion speed and reduces surgical time.<\/li>\n<li>The self-tapping active apex facilitates insertion even in cases of undersized drilling.<\/li>\n<li>The transverse apical vents collect bone detritus during the insertion, allowing for efficient bone integration and long-term stability.<\/li>\n<li>The optimised morphology results in high primary stability.<\/li>\n<li>The atraumatic apex protects anatomical structures.<span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/li>\n<\/ul>\n<h2><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><b><span data-contrast=\"auto\">ZinicMT and the Titansure\u00ae surface<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/h2>\n<p><span data-contrast=\"auto\">The chemical composition of the Titansure surface treatment, combined with the topographical characteristics of the implant, significantly improves the osseointegration process of Zinic MT.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The Titansure surface keeps Zinic MT free of contaminants and gives it a <strong>macro- and microporosity with optimal average values for fast and correct osseointegration<\/strong>, which at the same time increases the reliability and predictability of the implant.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<h2><b><span data-contrast=\"auto\">For which cases is ZinicMT indicated?<\/span><\/b><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/h2>\n<p><span data-contrast=\"auto\">ZinicMT is especially indicated for use in immediate or early loading and for cases of convergence or apical collapse. Its conical design facilitates low-density bone shaping and, due to being thinner than cylindrical implants, Zini MT is suitable for replacing practically any dental piece.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"auto\">The use of ZinicMT is recommended in the following clinical situations:<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<ul>\n<li><span data-contrast=\"auto\">Soft bone (type IV), where primary stability is difficult to obtain.<\/span><\/li>\n<li>Immediate placement in post-extraction sockets.<\/li>\n<li>Spaces with converging roots or adjacent teeth.<\/li>\n<li>Simultaneous graft and implant placement.<\/li>\n<li>Implant placement in sinus lift procedures.<\/li>\n<li>Aesthetic areas where bone preservation is the key.<\/li>\n<li>In bone structures lacking appropriate physical properties.<span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"auto\">Find out more about our <a href=\"https:\/\/ziacom.com\/en\/zinicmt-implant\/\" target=\"_blank\" rel=\"noopener\">ZinicMT conical connection<\/a> implant by contacting <a href=\"https:\/\/ziacom.com\/en\/contact\/\" target=\"_blank\" rel=\"noopener\">our sales network<\/a>.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559739&quot;:160,&quot;335559740&quot;:259}\">\u00a0<\/span>[\/vc_column_text]<div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":50,\"mobile\":30,\"smobile\":30}'><\/div>[vc_column_text]<\/p>\n<h2 style=\"font-size: 18px;\"><i>You may also like<\/i><\/h2>\n<p>[\/vc_column_text]<div class=\"deeper-spacer clearfix\" data-config='{\"desktop\":50,\"mobile\":30,\"smobile\":30}'><\/div>[vc_basic_grid post_type=\"post\" max_items=\"10\" item=\"51432\" grid_id=\"vc_gid:1669291299694-70a83bb6-b361-5\" taxonomies=\"1774, 1481\"][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_raw_js]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[\/vc_raw_js][vc_column_text] [\/vc_column_text][vc_column_text]The key to tapered implants such as the ZinicMT lies in their high primary stability, in other words, in the solidity and consistency they achieve at the bone-implant junction.<\/p>\n","protected":false},"author":1,"featured_media":90413,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1417,1424],"tags":[1772],"class_list":["post-107845","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-dental-implants","category-ziacom-products","tag-disassembling-zinicmt"],"_links":{"self":[{"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/posts\/107845","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/comments?post=107845"}],"version-history":[{"count":0,"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/posts\/107845\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/media\/90413"}],"wp:attachment":[{"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/media?parent=107845"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/categories?post=107845"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ziacom.com\/en\/wp-json\/wp\/v2\/tags?post=107845"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}