One of the great advances in implantology treatments is, unquestionably, immediate loading.
Its demand has increased considerably over the last few years, as the majority of patients wish to shorten treatment times and, at the same time, speed up the process in order to see (and enjoy) the final results as soon as possible.
Thanks to this technique, they are offered the possibility of having both the immediately loaded implants and the temporary fixed prosthesis fitted on the same day.
Immediate loading: great advantages for professionals and patients
The immediate loading technique is particularly effective in anterior restorations with high visibility and high aesthetic load.
It also has many other benefits:
- Improved aesthetics from the first moment, as well as functionality and comfort: the patient can speak and chew normally (although a soft diet is recommended during the first few days so in order not to submit the prosthesis to stress and, therefore, compromise the osseointegration process).
- Elimination of the need for removable prostheses.
- Shorter and more bearable postoperative period.
- Treatment times are reduced since immediate loading avoids a second surgery.
- Preservation of the soft tissues and remodelling of the gum, which is essential for the final aesthetic result of the treatment.
- Promoting bone tissue healing and osseointegration of implants into the bone.
- The provisional fixed piece does not overload the rest of the teeth.
It is not a technique suitable for all patients, and the dentist must carry out prior studies to identify if the characteristics of the person are suitable for this type of procedure. However, thanks to its features, Galaxy makes this technique possible for the vast majority of clinical profiles.
How do the immediate loading technique and Galaxy combine?
In addition to the patient fulfilling a series of characteristics when undergoing immediate loading treatment (such as having adequate hygiene and habits, not suffering from bruxism or presenting a correct occlusion), the characteristics of the implant used will be the key to the successful resolution of the treatment.
This is where Galaxy comes in, whose topographical properties make it perfect for immediate loading treatments on the same day.
Our conical morphology and connection implant offers predictability and efficiency to treatments, as its biomechanical foundations has been developed to provide a solution to any clinical need:
- The double thread design and its conical morphology improve mechanical retention and increase the capacity to withstand compressive forces (as well as to convert non-axial forces into compressive ones).
- Titansure Active, a surface treatment that promotes and accelerates osseointegration.
- The self-tapping active apex facilitates the rectification of the insertion axis in post-extraction alveoli.
- Available in various diameters and lengths to suit the clinical needs of each patient.
- Increases superior primary stability even in poor bone quality, also thanks to its threaded design.
- Conical connection prevents micromovement and microleakage at the implant-abutment interface.
- Ideal in tight spaces thanks to its narrow diameter of 3.4 mm.
- Reduced cortical stress thanks to its cervical reverse taper.
Therefore, it meets the indispensable requirements for a successful immediate loading treatment.